TECHNOAC - Cable locator and acoustic fault detector “Success ATG-127E”

  • Price: $ 4,450.00 + 18% VAT
    The Price Included VAT: 39,503.80 TL
Upon Order

Add to Wish List

Compare this Product

Availability: Upon Order

Brands TECHNOAC

Product Code: TCH11

Cable locator and acoustic fault detector “Success ATG-127E”

High tech kit with multi-frequency transmitter for buried utilities detection and acoustic cable fault detection.


Features:

  • High precision location of underground utilities up to 6 m
  • Transmitter - 120W, frequency range: 200 to 9999 Hz
  • Distance of tracing is 5 km from the place of transmitter connection
  • Detection of insulation deterioration on cables by non-contact methods: sharp decreasing of the signal level, by using the sensor DODK (extra tool), the phase "double-frequency" method "Δφ" and the amplitude of "double-frequency" the method of "ΔA"
  • Detection of insulation deterioration on cables by contact method : Sensor DKI (extra tool)
  • Receiver frequencies: 50(60) Hz / 100(120) Hz / 512 Hz / 1024 Hz / 8192 Hz / 33 kHz
  • Transmitter - 120W, frequency range: 200 to 9999 Hz
  • Storage of 31 signal level with a graph displayed
  • Visual indication of the signal on the display: scale, graph and spectrum
  • Graphic visualization (moving chart) of sequence of measurements, max and min signal levels
  • Sound indication
  • Choice of bandwidth
  • Two-segment indication of frequency spectrum (and “filtered”) signal
  • Light weight
  • Comfortable to wear for long terms
  • LCD display

Application:

  • Cable fault location by electromagnetic and acoustic methods (with high-voltage pulse transmitter, which is not included into the set)
  • Detection of insulation deterioration on cables by contact and non-contact methods
  • Detection of cables up to 6 m depth
  • Detection of metal pipelines up to 6 m depth
  • Survey the ground before the ground works
  • “Broadband” mode
  • Distance of tracing from the place of transmitter connection is up to 5 km
  • Indirect measurement of the depth


Standard Set

  • Receiver AP-027
  • Acoustic sensor AD-227
  • Carrying rod for AD-227
  • Extension carrying rod for AD-227
  • Contact rods for AD-227
  • Magnet for AD-227
  • Electromagnetic sensor EMD-247
  • Transmitter АG-120
  • Inductive antenna IEM-301.3
  • Headphones
  • Grounding rod
  • Cables and accessories


2 Year Warranty


Parameter

Tracing

Leak detection

Type of accepted signal

Continious /pulse

Continious signal

Frequencies of the receiver’s filter

Central frequency of quasi- resonant filter 50 to 60 Hz,100 to 450 Hz through 50 Hz, 120 to 540 Hz through 60 Hz, 512 Hz / 1024 Hz / 8192 Hz/ 33kHz

Range limitation "below" 0,1 / 0,15 / 0,21 / 0,31 / 0,45 / 0,65 / 0,95 / 1,38 kHz Range limitation

 "above" 2,00 / 1,38 / 0,95 / 0,65 / 0,45 / 0,31 / 0,21 / 0,15 kHz

«Broadband», (operating mode)

0,05 to 8,6 kHz

0,09 to 2,20 kHz

Gain factor

100 dB

120 dB

Visual indication

Liquid-crystal display-symbols and meaning of the chosen modes and parameters.

animated (moving) scale of the output signal level

digital value and animated (moving) scale of the output signal level

graphic (moving diagram) of the output signal level - frequency content of the output signal level

digital and graphic display of output signal levels kept in the "memory"

Sound indication

Headphones natural broadband or filtered signal

Headphones-synthesized sound. Frequency modulation

-

Built-in emitter - synthesized sound. Frequency modulation

-

Supply

Voltage 4…7 V. - alkaline batteries АА type 1,5 V (4 pcs.).

Time of continuous operation not less than

20 hours

Ambient temperature

-20°С to +50°С

Ingress protection rating

IP54

Receiver AP-027 dimensions

220 × 102 × 42 (mm)

Weight of the electronic unit

0,46 kg

Specifications of AG-120

Frequency of transmitted signal

Frequencies f1, f2, f3 (three frequencies fixed in memory), Hz

Range 200 to 9999 (selected in the range with a resolution of 1 Hz and accuracy of ±0,05% Hz and input in

the power- independent memory)

Frequency f4 (one «temporary»), Hz

Range 200 to 9999 (selected instead of one of the «fixed», not input to the memory, exists while the power is on)

Generation modes

Mode 1

Continuous «СО»

Mode 2 pulse duration, ms pulse rate, Hz

Short pulses transmission «РU» 350 0,7

Mode 3 Pulse duration, ms Pulse rate, Hz

Three frequencies (sent with alternation of frequencies f1, f2, f3) «3F» 350 1,4

Output parameters

Output current

Maximum in manual mode: - continuous and three frequencies generation, А - pulse generation, А

10 15

Specified for auto matching

Four values (I1, I2, I3, I4) Selected in the range 0,1 to 9,9 А with a resolution of 0,1А and kept in power-independent memory

Maximum output voltage

- when working in safe mode, V - under internal power supply, V - with added external accumulator 12V, V - when supplied from power adapter, V

24 220 330 140

 

2 Year Warranty